C & S Fire-Safe Services knows what it takes to keep Jacksonville, OR and the surrounding area safe!
Read our reviews and see how we have served Jacksonville, OR to our best abilities since 1977.
Local Reviews
for Jacksonville, OR
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting strong satisfaction and appreciation for the service provided. Customers consistently highlight professionalism, reliability, and efficiency as defining characteristics of their experience. There is a recurring theme of punctuality and excellent communication, with reviewers noting timely arrivals, clear explanations of work, and flexibility in scheduling. The tone is warm and enthusiastic, with many expressing gratitude for the thoroughness and knowledge demonstrated during service visits. Long-term customer relationships are evident, with several reviewers mentioning years of continued service, indicating sustained trust and satisfaction. The friendly and courteous demeanor of the service providers is frequently praised, contributing to a welcoming and professional atmosphere. Overall, the reviews convey a sense of confidence in the quality and dependability of the fire safety services, with customers feeling well-cared for and secure in their ongoing partnership.
Our Reviews by City
buildings maintenance supervisor
Jorge - Jacksonville, OR 97530
Fast response, awesome service.
Ryan - Jacksonville, OR 97530
Jason whent above and beyond to accommodate our company's needs. Will look forward to working with C&S in the future.
Thorough
Alana - Jacksonville, OR 97530
Jason was very thorough and very patient while explaining what he was looking for and the needs going forward.
Great service
FRAU - Jacksonville, OR 97530
Jason V.
Sprinkler Inspection
Jason V.
Sprinkler Inspection
Brice J.
Annual fire alarm test.
Garry Y.
Dallas H.
The customer called for a semi-annual inspection of their kitchen Amerex fire suppression system. I scheduled the appointment and arrived to do the service for them. I took the system offline and inspected each component of the system. I found no major defects or problems. I changed the fusible links and the low temp caps of the nozzles. I put the system back to operational mode and wrote a report for the customer. I let them know their next visit would be in 6 months.
Dallas H.
I was called by the customer to inspect their Kitchen Ansul Suppression System. I did a site survey and then proceeded to test it for any defects and if it would properly function. I changed out the fusible links and 5 rubber nozzle caps. I put the system back online and it is now in good working order. I let the customer know they were protected and could start cooking once again.
Dallas H.
Fire suppression inspection of the 2 Ansul Systems.
Gavin W.
Kitchen hood services performed on the Main Hood, the Prep Hood, the Pizza hood and the filters. We cleaned the inside of the hoods, the ducts and the fans. We found the fans will need a couple more cleanings to be 100%. Next service is due in February. We call to schedule the appointments 1-4 weeks in advance.
Dallas H.
Did the Annual fire extinguisher service and the semi-annual fire suppression inspection on the Ansul R102 3 gallon system. Checked the gauges and tagged the 7 fire extinguishers (they only needed to have an inspection done this round). The fire suppression system needed new links and nozzle caps this time. Everything is good to go.
Dallas H.
Fire system service/repairs
Garry Y.
Garry Y.
Jason V.
RISER IN BASEMENT: ANNUAL WET SPRINKLER INSPECTION 2ND FLOOR: ANNUAL WET SPRINKLER INSPECTION RISER IN BASEMENT: ANNUAL DRY SPRINKLER INSPECTION
Jason V.
ANNUAL WET SPRINKLER INSPECTION ANNUAL ANTI-FREEZE LOOP TEST
Jason V.
ANNUAL WET x1 /antifreeze loop testing x2
Jason V.
RISER IN BASEMENT: ANNUAL WET SPRINKLER INSPECTION 2ND FLOOR: ANNUAL WET SPRINKLER INSPECTION RISER IN BASEMENT: ANNUAL DRY SPRINKLER INSPECTION
Dallas H.
Jason V.
ANNUAL WET SPRINKLER INSPECTION. ANNUAL ANTIFREEZE LOOP TESTING.
Jason V.
RISER IN BASEMENT: ANNUAL WET SPRINKLER INSPECTION 2ND FLOOR: ANNUAL WET SPRINKLER INSPECTION RISER IN BASEMENT: ANNUAL DRY SPRINKLER INSPECTION
Mark R.
We appreciate your feedback. How did we do? Thank you!
Jason V.
Emergency Sprinkler Service Call Leaking Sprinkler Head.
Jason V.
ANNUAL WET SPRINKLER INSPECTION - RISER IN BASEMENT ANNUAL WET SPRINKLER INSPECTION - 2ND FLOOR ANNUAL DRY SPRINKLER INSPECTION - RISER IN BASEMENT
Tim O.
Tim O.
Jason V.
Service call-Sprinkler